z
ziyad_controls

Ziyad Y

@ziyad_controls

Controls and Electrical Troubleshooting Engineer

United States
English
About me
Electrical engineering candidate with 2 years of hands-on experience in data center HVAC building automation, controls and EPMS (power monitoring). I troubleshoot control systems and electrical faults and explain the fix in plain English: sequences that won't run, sensors reading wrong, points not communicating, PLC logic misbehaving, power monitoring data that doesn't add up. Tools: PLCs, Distech, Ignition SCADA, BACnet, EPMS and BAS platforms. Send your drawings, screenshots, trend logs and a description of the fault. I reply fast.... Read more

Skills

z
ziyad_controls
Ziyad Y
Offline • 
Average response time: 1 hour

See my services

Industrial Automation
I will troubleshoot your bas, hvac controls, plc or electrical faults

Work experience

Hanley_Energy

Mechanical/Electrical Controls Specialist

Hanley Energy • Full-time

Oct 2026 - Present • 1 mo

Support systems integration for mission-critical data center infrastructure, specializing in liquid cooling equipment and Electrical Power Monitoring Systems (EPMS). • Prepare point-to-point wiring diagrams, startup procedures, and pre-commissioning checklists for EPMS, BMS, liquid cooling, UPS, switchgear, and automatic transfer switches. • Coordinate with vendors, general contractors, and clients to resolve equipment and integration discrepancies and support project delivery. • Execute L2/L3 testing and partial functional testing; support L4/L5 commissioning activities following internal verification. • Deploy, commission, and troubleshoot control logic and network architectures using OPC-UA, Modbus TCP/IP, and RS-485 across multi-vendor power and cooling equipment.

RoviSys

Data Center Controls Engineer

RoviSys • Full-time

Jan 2026 - Oct 2026 • 9 mos

• Developed, deployed, and analyzed PLCnext control logic supporting mission-critical power monitoring and high-availability infrastructure. • Configured Ignition tag registries and OPC-UA architectures across primary and redundant gateways to maintain reliable data flow. • Supported historian/database connections, security certificates, and communication-port configuration in hardened network environments. • Integrated Moxa, Eaton, CAT, Phoenix Contact, Juniper, and Janitza equipment using RS-485, Modbus TCP/IP, and Industrial Ethernet. • Performed field diagnostics using thermal imaging, electrical diagrams, and digital/analog signal verification to isolate system issues. • Prepared technical submittals, redlined peer documentation, and coordinated resolution of equipment callout discrepancies.